  1description electronic monitoring rela y for temperature monitoring emd-bl-ptc(-pt) ? phoenix contact - 2016-05-10 data sheet safety and system availability re quirements are constantly on the increase ? across all industries. processes are becoming more and more complex, not only in machine building and the chemical industry but also in building technology. the de- mands placed on energy techno logy are also constantly on the rise. it is only by continuously mo nitoring key network and system parameters that erro r-free and therefore co st-effective opera- tion can be achieved. electronic monitoring relays from the emd series are available for a wide range of monitoring tasks so that the consequenc es of errors can be avoided or kept wi- thin limits. the operating states are signaled via colo r leds and any er- rors that occur can be sent to a controller via a floating contact or can shut down a section of the system. all device versions are equipped with response dela ys so that measured values outside the set monitoring range can be briefly tolerated. warning: risk of electric shock never carry out work when voltage is present. make sure you always use the latest documentation. it can be downloaded from the product at phoenixcontact.net/products. ? winding temperature monitoring 107385_en_00 features
emd-bl-ptc(-pt) 107385_en_00 phoenix contact 2 description ty p e order no. pcs./pkt. electronic monitoring relay for temp erature monitoring EMD-BL-PTC-PT 2906253 1 electronic monitoring relay for temperature monitoring emd-bl-ptc 2906252 1 input data input name measuring input maximum input voltage 4 v dc (connection terminal blocks: t1 and t2) maximum temperature coefficient < 0.05 %/k function winding temperature monitoring basic accuracy 10 % (of scale end value) total cold resistance 1.5 k ? response value 3.6 k ? (relay drops out) release value 1.6 k ? (relay picks up) short-circuit detection < 20 ? recovery time > 300 ms output data contact type 1 floating pdt maximum switching voltage 250 v ac (in acc. with iec 60947-5-1) interrupting rating (ohmic load) max. 1250 va (5 a/250 v ac) output fuse 5 a (fast-blow) supply supply voltage 230 v ac (-15 % ... +10 %) frequency range 50 hz ... 60 hz nominal power consumption 3.5 va (0.5 w) general data mechanical service life 15 x 10 6 cycles service life, electrical 1 x 10 5 cycles switching frequency 6 voltage drop > 30 % (relative to the supply voltage) operating mode 100% operating factor degree of protection ip40 (housing) / ip20 (connection terminal blocks) degree of pollution 2 (iec 60947-5-1) overvoltage category iii (iec 60947-5-1) mounting on standard din rail ns 35 in accordance with en 60715 mounting position any width 17.5 mm height 88 mm depth 65.5 mm type of housing polyamide pa66, self-extinguishing color gray 2ordering data 3 technical data
emd-bl-ptc(-pt) 107385_en_00 phoenix contact 3 connection data push-in-/spring-cage connection screw connection conductor cross section, solid 0.14 mm2 ... 2.5 mm2 0.5 mm2 ... 2.5 mm2 conductor cross section, flexible 0.14 mm2 ... 2.5 mm2 0.5 mm2 ... 2.5 mm2 awg 26 ... 14 20 ... 14 stripping length 8 mm 8 mm tightening torque 1 nm ambient conditions ambient temperature (operation) -25 c ... 55 c ambient temperature (storage/transport) -25 c ... 70 c permissible humidity (operation) 15 % ... 85 % climatic class conformance / approvals conformance ce-compliant ul, usa / canada ? conformance with emc directive 2004/108/ec (valid until ap ril 19, 2016) / 2014/30/eu (valid from april 20, 2016) noise immunity according to en 61000-6-2 noise emission according to en 61000-6-3 conformance with low voltage directive 2006/95/ec (valid un til april 19, 2016) / 2014/35/eu (valid from april 20, 2016) low voltage switchgear according to en 60947-5-1
emd-bl-ptc(-pt) 107385_en_00 phoenix contact 4 4block diagram t1 t2 a1 12 11 14 u = 230 v ac a2 5safety notes warning: risk of electric shock never carry out work when voltage is present. 6structure u failure emd-bl --pt ptc t1 a1 a2 1 2 3 t2 1 led: failure 2 led: supply u 3 snap-on foot for din rail mounting 7 installation the module can be snapped onto all 35 mm din rails acco rding to en 60715. warning: risk of electric shock never carry out work when voltage is present.
emd-bl-ptc(-pt) 107385_en_00 5 phoenix contact gmbh & co. kg ? 32823 blomberg ? germany phoenixcontact.com 8diagnostics the leds indicate the following error states: "u" led (green) ? led on: supply voltage present "failure" led (red): ? led on: indicates error 9 connection examples u r a1 a2 a1 a2 t1 t2 11 12 14 11 12 14 10 function led 3,6 k 1,6 k ptc r failure temperature monitoring of the motor winding if the ptc total resistance is less than 3.6 ? k ? (normal tempe- rature of the motor) when the supply voltage is applied, the output relay r activates. if th e total resistance rises over 3.6 ? k ? , the output relay r deactivates. the output relay r re- activates when the ptc total resistance has fallen below 1.6 ? k ? .


▲Up To Search▲   

 
Price & Availability of EMD-BL-PTC-PT

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X